Removal, Control Panel Disassembly, Control and Power Module Removal, Cooling System, Electronic Control, Fan, NTC Sensors, Temperature Alarm, NTC Failure, Damper Microswitch Malfunction, Door Microswitch Malfunction, Refrigerant Circuit Opening, Suction Side Leaks, Fault Diagnosis , Condensation in the refrigerator compartment, The refrigerator compartment is not cold enough. Wiring Diagrams
Main PCB PDF Free Download
Bosch B26FT70SNS Repair Manual | Download |
Bosch KAN58A40AU Repair Instruction – 26.03.2015 | Download |
Bosch B22CS50SNW-01 General Repair - Instruction | Download |
Bosch KIN85NSF0G Repair Hints 9001628069 Fridge-freezer | Download |
Bosch B20CS50 (FRU-546D) B20CS80 (FRU-546E) Service Manual | Download |
Bosch Nevera Refrigerador Ksu 40 Primiun Electronica Diagrama | Download |
Bosch No Frost Service Manual Circuito Hermético | Download |
Bosch Refrigerator KGU Service Manual | Download |
Bosch KSU 29 KSU 31 KSU 33 KSU 36 KSU 37 KSU 38 MANUAL DE USO USER`S MANUAL REFRIGERATOR DOMESTIC USE |
Download |
Bosch KSU40 KSU44 KSU40i KSU44i INSTRUCTIONS MANUAL | Download |
Bosch KGS3775 - 09 Operating Instructions | Download |
Bosch B20CS51SNS/02 Free standing refrigerator side by side freestanding Repair Manual |
Download |
The refrigerator compartment does not work at all or the temperature is higher than normal
The evaporator heating element is faulty - this failure is typical for Bosch refrigerators with a No Frost freezing system. The heating element of the evaporator is located in the freezer, therefore, if the heater is faulty, defrosting does not occur and the evaporator is covered with a heavy layer of frost.
The solution to the problem is to replace the evaporator heater with a new one.
Thermostat failure - This happens because the thermostat does not give the required command and does not stop cooling. Thus, the refrigerator compartment does not receive cooling, and the freezer ends up with a large layer of snow and ice. In this case, you will need to replace the thermostat.
Freon leakage - it can occur due to mechanical damage to the circuit, at joints, or the drainage system is clogged. If such a breakdown occurs, the refrigerator will need to be refilled with freon.
The fan motor burned out - such a breakdown is typical only for Bosch refrigerators with a No Frost freezing system. The fan that blows cold air into the refrigerator compartment may fail. If such a breakdown occurs, the fan motor should be replaced.
An unnaturally loud noise is heard when the refrigerator is operating
Compressor wear - this breakdown is typical of older models of refrigerators that have been in operation for a long time. It is not the compressor itself that wears out, but its individual parts, most often the pistons and their rings. In this case, a loud hum may be heard when the compressor operates,
It is necessary to adjust the shock absorbers - during its operation, the compressor not only produces a sound of a certain power, but also vibrates. To prevent these vibrations from creating additional noise, the compressor is equipped with shock absorbers. Accordingly, if the shock absorbers are weakened, compressor vibrations can create additional noise
The fan makes noise - this malfunction is typical for Bosch refrigerators with a No Frost freezing system. The fan located in the freezer compartment makes noise. If the noise from it becomes loud, most likely, a layer of ice has formed around, and the fan is catching it with its blades.
The freezer compartment does not work well or does not work at all
The air sensor is faulty - it is located in the freezer. If a faulty sensor is detected, it no longer transmits information to the control unit about the temperature status in the freezer.
The solenoid valve is faulty - a breakdown that is typical for refrigerators with a dry freezing system. In this case, the valve does not switch to cooling the freezer chamber and continues to work to cool the entire unit and all its chambers.
Freon leak – a freon leak can also cause a freezer malfunction. In this case, the temperature in the freezer may be higher than normal or the freezer may not work at all.
Chian -TILUNG ABRAHAM (Thursday, 21 November 2024 22:58)
How can I get a service manual for bish refrigerator type K1. Kbm30us. My cell is 3476283944 my email is cabrahamcompanies@yahoo.com
Mario (Thursday, 05 September 2024 04:40)
Hi.
I require a wiring diagram for a bosch refrigerator-freezer, model kgu44121.
It would be highly appreciated if you could help.
Thanks
Best Regards