Error codes for Ariston dryers in modern models are displayed directly on the display; after reading the corresponding table, you can easily identify the fault and be able to take measures to eliminate it. If the situation requires it, you should call a specialist,
The Italian brand Ariston maintains popularity among the population, being one of the leaders in the production and sale of household appliances. The creators of the units pay special attention to the quality of the products, which attracts the target audience, but breakdowns during operation are still inevitable. It should be understood that a malfunction can be expressed by the failure of a part, and sometimes the failure is non-systemic in nature and can be easily mitigated by the owner of the unit.
Fault | Description | How to fix the problem yourself |
F1 | Motor thyristor short circuit. | Inspect the thyristor circuit. If there is a break, carry out repairs. Replace the part if faulty. |
F2 | The motor does not rotate. Motor or fan blocked. | Check the specified nodes. Remove foreign objects that interfere with normal operation. Inspect the wiring and contacts. |
F3 | Open circuit or short circuit of the thermistor circuit. Failure of the NTC sensor, main processor. |
Diagnose: Thermistor circuit; NTC sensor; CPU. Install the correct items. |
F4 | The air pump is not working. | Diagnose the air pump and its circuit. Connect the new node. |
F5 | The air pump does not give a signal. | Inspect the wiring, tighten the contacts from the board to the pump. Clean oxidized contacts. |
F8 | Heater relay malfunction. | Diagnose and replace relay if necessary. |
F9 | The software crashed. | Contact the service center. |
F10 | Poor air flow from heating element. | Clean the heating element. |
F11 | There is no contact with the pumping device. | Check the circuit and connections of the device. Replace the supercharger if it breaks. |
F12 | There is no communication between the display and the control board. | Inspect the wiring, tighten the contacts. Install a working board. |
F13 | The temperature controller circuit has broken. | Wiring repair. |
F15 | The heating element relay is broken, its circuit is open or short-circuited. | Diagnose relays, wiring, connections. Install work items. |
F17 | The power element has failed. | Repair the part. |
Fault | LED 1 | LED 2 | LED 3 | LED 4 | LED 5 |
F1 | OFF | OFF | OFF | FLASH | OFF |
F2 | OFF | OFF | FLASH | OFF | OFF |
F3 | OFF | OFF | FLASH | FLASH | OFF |
F4 | OFF | FLASH | OFF | OFF | OFF |
F5 | OFF | FLASH | OFF | FLASH | OFF |
F6 | OFF | FLASH | FLASH | OFF | OFF |
F7 | OFF | FLASH | FLASH | FLASH | OFF |
F8 | FLASH | OFF | OFF | OFF | OFF |
F9 | FLASH | OFF | OFF | FLASH | OFF |
F10 | FLASH | OFF | FLASH | OFF | OFF |
F11 | FLASH | OFF | FLASH | FLASH | OFF |
F12 | FLASH | FLASH | OFF | OFF | OFF |
F13 | FLASH | FLASH | OFF | FLASH | OFF |
F14 | FLASH | FLASH | FLASH | OFF | OFF |
F15 | FLASH | FLASH | FLASH | FLASH | OFF |
F16 | OFF | OFF | OFF | OFF | FLASH |
F17 | OFF | OFF | OFF | FLASH | FLASH |
F18 | OFF | OFF | FLASH | OFF | FLASH |